Universal Lobe Series - Positive Displacement Pumps
DIMENSIONS & SPECIFICATIONS
MODEL 018-UL
0-1000 RPM speed range. 1½" (38.1 mm) port size; suitable to 200 PSI (13.8 bar) differential pressure. Temperature range -40°F (-40°C) to 300°ÌýF (149°C).
Ìý Ìý
|
A
|
AO
|
B
|
CP
|
CP1
|
CP4
|
D
|
E
|
F
|
G
|
I
|
J
|
L
|
O
|
U
|
X
|
2X
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IN
|
4.75
|
8.3
|
3.75
|
12.37
|
14.59
|
15.58
|
5.50
|
1.94
|
2.31
|
.41 slot
|
7.66
|
2.93
|
9.84 |
4.21
|
.875
|
3.49
|
6.97
|
MM
|
121
|
211
|
95
|
314
|
371
|
396
|
140
|
49
|
59
|
10 slot
|
194
|
74
|
250
|
107
|
22.23
|
89
|
177
|
CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection size for Jacketed Covers is "-14 NPT.
Dimension "X" and "2X" apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.
Approximate shipping weight 65 lb. (29.5 kg.).
NOTES: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed. Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.
Pump Curve 95-07089 - Lobe Pump Model 018 || PDF
MODEL 030-UL
0-1000 RPM speed range. 1½" (38.1 mm) port size; suitable to 200 PSI (13.8 bar) differential pressure. Temperature range -40°F (-40°C) to 300°ÌýF (149°C).
Ìý Ìý
|
A
|
AO
|
B
|
CP
|
CP1
|
CP4
|
D
|
E
|
F
|
G
|
I
|
J
|
L
|
O
|
U
|
X
|
2X
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IN
|
6.25
|
10.29
|
4.25
|
14.49
|
16.49
|
17.58
|
6.86
|
2.31
|
2.56
|
.41slot
|
8.83
|
3.56
|
11.63
|
5.21
|
1.25
|
4.25
|
8.5
|
MM
|
159
|
261
|
108
|
368
|
419
|
447
|
174
|
59
|
65
|
10 slot
|
224
|
90
|
295
|
132
|
31.75
|
108
|
216
|
CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection size for Jacketed Covers is "-14 NPT.
Dimension "X" and "2X" apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.
Approximate shipping weight 130 lb. (59.0 kg.).
NOTES: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed. Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.
Pump Curve 95-07082 - Lobe Pump Model 030 || PDF
MODEL 060-UL
0-1000 RPM speed range. 1½" (38.1 mm) port size; suitable to 200 PSI (13.8 bar) differential pressure. Temperature range -40°F (-40°C) to 300°F (149°C).
Ìý
Ìý
|
A
|
AO
|
B
|
CP
|
CP1
|
D
|
E
|
F
|
G
|
I
|
J
|
L
|
O
|
U
|
X
|
2X
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IN
|
8.25
|
15.31
|
5.87
|
18.26 |
21.00
|
9.56
|
3.50
|
4.12
|
.53
|
10.99
|
5.06
|
11.94
|
7.31
|
1.625
|
5.37
|
10.75
|
MM
|
210
|
389
|
149
|
464 | 533 |
243
|
89
|
105
|
.13
|
279
|
129
|
303 |
186
|
41.28
|
136
|
273
|
CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection size for Jacketed Covers is ¾"-14 NPT.
Jacketed Covers is ¾"-14 NPT.
Dimension "X" and "2X" apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.
Approximate shipping weightÌý285 lb. (129 kg.).
NOTES: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed. Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.
Pump Curve 95-07083 - Lobe Pump Model 060 || PDF
MODEL 130-UL
0-1000 RPM speed range. 1½" (38.1 mm) port size; suitable to 200 PSI (13.8 bar) differential pressure. Temperature range -40°F (-40°C) to 300°ÌýF (149°C).
Ìý
|
A
|
AO
|
B
|
CP
|
CP1
|
CP4
|
D
|
E
|
F
|
G
|
I
|
J
|
L
|
O
|
U
|
X
|
2X
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IN
|
8.25
|
15.31
|
5.87
|
20.15
|
22.27
|
23.84
|
9.56
|
3.50
|
4.12
|
.53
|
10.99
|
5.06
|
15.77
|
7.31
|
1.625
|
5.37
|
10.75
|
MM
|
210
|
389
|
149
|
512
|
566
|
606
|
243
|
89
|
105
|
13
|
279
|
129
|
401
|
186
|
41.28
|
136
|
273
|
CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection size for Jacketed Covers is ¾"-14 NPT.
Dimension "X" and "2X" apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.
Approximate shipping weight 305 lb. (138 kg.).
NOTES: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed. Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.
MODEL 220-UL
0-1000 RPM speed range. 1½" (38.1 mm) port size; suitable to 200 PSI (13.8 bar) differential pressure. Temperature range -40°F (-40°C) to 300°ÌýF (149°C).
Ìý Ìý
|
A
|
AO
|
B
|
CP
|
CP1
|
CP4
|
D
|
E
|
F
|
G
|
I
|
J
|
L
|
O
|
U
|
X
|
2X
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IN
|
8.50
|
19.13
|
9.00
|
24.00
|
26.06
|
29.25
|
12.38
|
3.75
|
7.25
|
.53 slot
|
14.80
|
6.38
|
18.49
|
9.38
|
2.00
|
6.63
|
13.25
|
MM
|
216
|
486
|
229
|
610
|
662
|
743
|
314
|
95
|
184
|
13 slot
|
376
|
162
|
470
|
238
|
50.80
|
168
|
337
|
CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection size for Jacketed Covers is "-14 NPT.
Dimension "X" and "2X" apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.
Approximate shipping weight 590 lb. (268 kg.).
NOTES: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed. Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.
Pump Curve 95-07085 - Lobe Pump Model 220 || PDF
MODEL 320-UL
0-1000 RPM speed range. 1½" (38.1 mm) port size; suitable to 200 PSI (13.8 bar) differential pressure. Temperature range -40°F (-40°C) to 300°ÌýF (149°C).
Ìý Ìý
|
A
|
AO
|
B
|
CP
|
CP1
|
CP4
|
D
|
E
|
F
|
G
|
I
|
J
|
L
|
O
|
U
|
X
|
2X
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IN
|
12.00
|
22.38
|
11.63
|
27.66
|
29.16
|
--
|
13.88
|
5.25
|
8.00
|
.66
|
17.80
|
6.88
|
21.63
|
10.38
|
2.375
|
8.00
|
16.00
|
MM
|
305
|
568
|
295
|
703
|
741
|
--
|
358
|
133
|
203
|
17
|
452
|
175
|
549
|
264
|
60.45
|
203
|
406
|
CP= Standard Cover, CP1= Jacketed Cover, CP4= Manual Vented Cover, Connection size for Jacketed Covers is "-14 NPT.
Dimension "X" and "2X" apply for Bevel Seat, "S"-Clamp, "Q"-Clamp, 15I and 14I fittings.
Approximate shipping weight 895 lb. (406 kg.).
NOTES: Dimensions are for guidance purposes only. Contact your WCB Representative if more detailed measurements are needed. Waukesha Cherry-Burrell (WCB) curves are intended for use as an aid for preliminary selection of pumps by trained and qualified engineers. All selections must be reviewed by authorized WCB personnel prior to placing an order. WCB is not responsible for unauthorized or incorrect selections resulting from the use of these curves.
Pump Curve 95-07145 - Lobe Pump Model 320 || PDF